Radon in Spain: Regulations, Risk Management, and Environmental Due Diligence

28/10/2026

Radon is a naturally occurring radioactive gas produced by the decay of uranium in the Earth’s crust. It migrates through pores in soil and rock towards the surface, where it disperses into the atmosphere. Health risks may arise when radon enters buildings and accumulates indoors, particularly where ventilation or protective measures are insufficient. As radon is colourless, odourless and tasteless, its presence can only be established through appropriate measurements. 

Exposure to elevated indoor radon concentrations poses significant health risks. Radon is classified as a Group 1 carcinogen by the International Agency for Research on Cancer (IARC) and is recognised as the second leading cause of lung cancer after smoking, and the leading cause among non-smokers. Appropriate assessment and mitigation measures are therefore important in buildings where exposure may occur. 

Radon potential is influenced by geological factors, including uranium content, soil and rock permeability, and geological structures. Areas of Spain with elevated radon potential include parts of:

  1. Galicia
  2. Asturias
  3. Extremadura
  4. Castilla y León
  5. Catalonia

 Indoor radon concentrations also depend on building characteristics, floor level, occupancy patterns and ventilation. Measurements inside buildings are therefore necessary to assess actual exposure. Basements and ground-floor spaces may be more susceptible because of their proximity to the ground.

 Radon can enter buildings through cracks in floors and walls, joints, service penetrations and other openings in contact with the ground. The effectiveness of ground barriers and ventilation systems can significantly influence indoor concentrations

Illustration 1: Common radon gas entry pathways in buildings[NN1.1] (Source: National Radon Action Plan (Ministry of Health (Ministerio de Sanidad)), 2024).
Illustration 1: Common radon gas entry pathways in buildings[NN1.1] (Source: National Radon Action Plan (Ministry of Health (Ministerio de Sanidad)), 2024).

In 2017, the Spanish Nuclear Safety Council (Consejo de Seguridad Nuclear, CSN) published a radon potential map to illustrate the geographical distribution of estimated indoor radon concentrations across Spain. The mapping draws on available measurements and geological information. 

Radon potential is expressed as the 90th percentile (P90) of the distribution of indoor radon concentrations in buildings within a given area. Approximately 90% of buildings are expected to have concentrations below the P90 value, while approximately 10% may exceed it. This does not mean that 10% of buildings in every area exceed the Spanish reference level of 300 Bq/m³. Areas with a P90 value above 300 Bq/m³ indicate a greater potential for elevated indoor radon concentrations. 

The map is a screening tool rather than a substitute for measurements in individual buildings.

Illustration 2: Radon Potential Map of Spain (Source: CSN, 2017).
Illustration 2: Radon Potential Map of Spain (Source: CSN, 2017).

In Spain, radon-related requirements arise principally from the Technical Building Code (Código Técnico de la Edificación, CTE), as amended by Royal Decree 732/2019, and the radiation protection framework established by Royal Decree 1029/2022. 

These frameworks address different contexts: protection against radon entry in buildings and assessment and control of occupational exposure in workplaces. 

RD 732/2019 — Building design perspective

·        Basic Document DB-HS 6 (Protection against Radon Exposure) of the Spanish Technical Building Code (CTE), introduced by Royal Decree 732/2019 addresses protection against radon exposure in buildings within its scope. The provisions became mandatory in September 2020, subject to applicable transitional arrangements.

·       Depending on the municipality and the type of building work, DB-HS 6 requires measures designed to limit indoor radon entry. The applicable municipalities are identified in its Appendix B; the CSN radon potential map provides useful supporting context but does not replace the CTE classification.

·        For screening purposes, municipalities can be described as follows:

o   Municipalities not listed in Zones I or II: no location-based measures are prescribed by DB-HS 6 solely on this basis; elevated indoor radon concentrations cannot be ruled out.

o   Zone I: radon protection measures are required, using the construction solutions permitted by DB-HS 6.

o   Zone II: more stringent protection measures are required, generally involving a protective barrier combined with additional measures, such as ventilation or depressurisation of the ground beneath the building, in accordance with DB-HS 6 

RD 1029/2022 — Occupational exposure perspective

·       Royal Decree 1029/2022 establishes the radiation protection framework applicable to occupational exposure to radon. Employers and operators must consider whether their workplaces fall within the situations requiring radon measurements and, where applicable, implement measures to control exposure.

·       Article 75 addresses mandatory measurements in specified workplaces, including:

o   Workplaces where underground water is processed, handled or used, such as thermal establishments, in the circumstances specified in Article 75.

o   Underground workplaces, including mines, tunnels and caves, where relevant activities are carried out.

o   Workplaces situated on the ground floor or below ground in municipalities identified as priority areas under the applicable rules. 

CSN Instruction IS-47 (2025) identifies priority municipalities as those classified within Zone II of Appendix B of Basic Document DB-HS 6 of the Spanish Technical Building Code (CTE). 

The Instruction establishes specific requirements for radon measurements in workplaces located on the ground floor or below ground level within these municipalities, including the number and placement of detectors, measurement duration, laboratory accreditation, reporting and periodic reassessment.

Radon measurements must be conducted for at least three months between October and May, or over a full year using measurement periods of no more than three months. The frequency of subsequent measurements depends on the measured radon concentrations and the mitigation measures implemented, with reassessment intervals generally ranging from five to ten years, as established in CSN Instruction IS-47.

.

Radon assessment in Environmental Due Diligences by MediTerra

Radon is a naturally occurring radioactive gas that may pose an indoor air quality and occupational health risk. Elevated radon concentrations are generally associated with natural geological conditions and do not, in themselves, constitute evidence of soil contamination under Spanish contaminated land legislation. As part of an Environmental Due Diligence assessment, radon-related risks can be evaluated through a review of the property’s location in relation to radon-prone areas, applicable regulatory requirements, building characteristics and available indoor radon measurement records. Where relevant, further measurements or mitigation measures may be recommended.

Non-compliance may create additional costs or liabilities for owners, employers or prospective purchasers, such as:

  •    Requirements for radon measurements and exposure assessments.
  •    Mitigation measures and associated refurbishment or redevelopment costs.
  •    Occupational health and safety obligations and potential regulatory non-compliance.
  •    Potential post-acquisition liabilities and follow-up monitoring. 

Because radon exposure is highly dependent on site-specific conditions, elevated radon potential does not necessarily mean that indoor concentrations exceed the reference level. Actual concentrations must be established through appropriate measurements. MediTerra supports clients in identifying radon-related risks and regulatory obligations as part of EDD in Spain, providing practical recommendations for acquisitions, leasing, redevelopment and portfolio management.

 

References:

  • Royal Decree 732/2019 – Technical Building Code, DB-HS 6.
  • Royal Decree 1029/2022 – Radiation Protection Regulations.
  • CSN Instruction IS-47 (2025).
  • National Radon Action Plan (2024).
  • CSN Radon Potential Map (2017).